Back to top
08071794277
Send SMS Send Inquiry
FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL
FIRE CLOCK DISPLAY AND CONTROL PANEL
FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL FIRE CLOCK DISPLAY AND CONTROL PANEL

FIRE CLOCK DISPLAY AND CONTROL PANEL

65000.00 INR/Number

Product Details:

  • Product Type FIRE SAFETY
  • Standby Current 5 PPM
  • Control Distance 2000 Meter (m)
  • Alarm time 05 Hours
  • Usage FIRE & SAFETY
  • Dimension (L*W*H) 48 X 36 X 4 Inch (in)
  • Alarm startup time 30 Minutes
  • Click to View more
X

FIRE CLOCK DISPLAY AND CONTROL PANEL Price And Quantity

  • 65000.00 INR/Number
  • 151000 Number

FIRE CLOCK DISPLAY AND CONTROL PANEL Product Specifications

  • 2000 Meter (m)
  • 5 PPM
  • 230
  • FIRE SAFETY
  • 48 X 36 X 4 Inch (in)
  • FIRE & SAFETY
  • 05 Hours
  • 32
  • RED AND GREEN
  • 30 Minutes
  • AUDIO
  • Industry
  • 12 Volt (v)
  • 1.5 Millimeter (mm)
  • 230 Volt (V)
  • ABS
  • PUSH SWITCH
  • SWITCH
  • 55 Celsius (oC)
  • 60 Kilograms (kg)
  • 730 Days
  • RED
  • 1
  • 2 Ampere

FIRE CLOCK DISPLAY AND CONTROL PANEL Trade Information

  • NEW DELHI
  • 10 Number Per Month
  • 15 Days
  • Contact us for information regarding our sample policy
  • WOODEN PACKAGING
  • Australia North America South America Western Europe Middle East Africa Central America Eastern Europe Asia
  • All India
  • NIL

Product Description

 No Fire  All Clear Safe  Normal Red Led Signal . All Red Signal Are Used For Fault Signal . Customer Can Choice Display Mode  Any One Of Healthy  Situation Of Plant  When Actuate The Fault Location Following Blinking Display Will Be Closed And Fault Location Will Be Glow On The Fire Clock Display Unit Until  Push The Reset Button From The Control Panel  230 Volt Ac Input And Output Voltage 12 Volt Dc 2 Amp.  12 Volt Dc  Hooter Available 80db . Sound Range 200 Meter Distance. A Receiving Circuit Has Available Inside The Fire Clock Display Unit  It Is Called Receiver Section And A Control Circuit Has Available Inside The Control Panel It Is Called Transmitting Section Two Core 1.5 Sq.mm Cable Will Be Use For Power Supply And Multi Core Cable Can Use For Multiple Signal Of Each Line And One Core Will Be Used For Common Signal Connection For Multiple Zone .no Fire  All Clear Safe  Normal  Red Led Signal . All Red Signal Are Used For Fault Signal . Customer Can Choice Display Mode  Any One Of Healthy  Situation Of Plant .  When Actuate The Fault Location Following Blinking Display Will Be Closed And Fault Location Will Be Glow On The Fire Clock Display Unit Until  Push The Reset Button From The Control Panel   230 Volt Ac Input And Output Voltage 12 Volt Dc 2 Amp  12 Volt Dc  Hooter Available 80db . Sound Range 200 Meter Distance. A Receiving Circuit Has Available Inside The Fire Clock Display Unit  It Is Called Receiver Section And A Control Circuit Has Available Inside The Control Panel It Is Called Transmitting Section   Two Core 1.5 Sq.mm Cable Will Be Use For Power Supply And Multi Core Cable Can Use For Multiple Signal Of Each Line And One Core Will Be Used For Common Signal Connection For Multiple Zone  
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Fire Alarm' category